Diver-MOD
The Diver-MOD is the Modbus interface used to connect Divers to an RS485 network.
The Diver-MOD is the Modbus interface used to connect Divers to an RS485 network.
The Diver-MOD is the Modbus interface for Divers and is used to connect Divers to an RS485 network using the Modbus/RTU protocol. The Diver-MOD features a barometric sensor, which can be used to convert the Diver pressure in to a water level.
A typical Modbus configuration is illustrated in the figure below. In the schematic, two Diver-MODs are connected to a PC/PLC. This connection includes both data communication and power. The maximum Modbus cable length depends on the baud rate, the cable, the network configuration (2-wire or 4-wire), etc. A maximum length of 1000 meters can be achieved using the right components.
For more information visit the Frequently Asked Questions page for the Diver-MOD.
Dimensions (L × W × H) Material Protection classification | 65 × 50 × 35 mm ABS IP65 |
Communication Multidrop | RS485 half-duplex yes, max 8 devices |
External supply voltage Stand-by current | +5 to +12 Volt 2 mA |
Value | Unit | |
Range | 400 to 1100 | cmH2O |
Accuracy* | ±2.0 | cmH2O |
Resolution | 0.06 | cmH2O |
Value | Unit | |
Range | -20 .. +80 | °C |
Accuracy* | ±1.0 | °C |
Resolution | 0.2 | °C |
* maximum
Part No |
AS339 |